Small Medical Waste Incinerator 2 combustion chambers with scrubber


Small Medical Waste Incinerator 2 combustion Room with scrubber for Virus medical waste

On-Site Incineration Solution‎

Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, 
and medical research facilities. These wastes include both infectious (“red bag”) 
medical wastes as well as non-infectious, general housekeeping wastes.

1st. Chamber Temperature
Items/Model
Chimney
220V
 
Yes
100L or More(Optional)
Feed Capacity
Secondary Chamber
0.5Kw
Average 16
Temperature Protection
Power
Feed Door
Four Digital Screen
Smoke Filter Chamber
Internal Dimensions
330L
175x120x140cm
Stainless Steel
55x50cm
Burn Rate
Temperature Monitor
Average 60kg per feeding
Oil Consumption (kg/hour)
2.0 Sec.
5Meter or More(Optional)
Chimney Type
External Dimensions
Average 11.7
Gross Weight
Residency Time
4000kg

Items/Model

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-27


Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 Squander


Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 


Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower


Model

YD-150

Burning Rate

Typical 150 kgs/hour

Feed Capacity

Average 300 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Gas Form

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17–36 kg/hour

Gas Consumption (Natural Gas)

11–36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary Room )

External Dimensions

240 x 170 x 380cm (without chimney)

Infection Monitor

Yes

Oil Tank Capacity(if oil Gas )

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

before start the 2nd burner, full close all air valve on the 1st chamber. other operation keep same. 
reason: at the first 10-20 min burnning the plactic waste, deflagration combustion in the chamber. 
after 10-20 min, gradually increase air injection by air valve on the 1st chamber.
meanwhile, proposal 20-30 min burnning of the 1st chamber, stop the 1st burner(stop fire only, the fan inside the burner 
still working), let the plastic burn itself(Spontaneous combustion) to save diesel oil.
a small waste to energy project to turn municipal solid waste 

7500 kgs

Model

YD-150

Main Product List

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Smoke Filter Chamber(Dry Scrubber)

 

Incinerator Control Case(PLC Auto.Type)

 

Chimney:10.0Meters

Chimney (upgrade to Stainless Steel, free Price )

 

Italy oil/gas burner: 02 sets

 

Oil Tank (if oil fuel): 300Liters

 

Optional Part:

Stainless Steel Wet scrubber(Cooling Spray Coating )

into electricity. The project is to cater for a local council with a population of around 60,000 people and will serve as a 
pilot project. If project is successful than other such plants will be installed in other towns and villages. The villages 
will all cater for the MSW in their locality instead of a central large incineration plant to cate for the whole county.for a 7 ton per 
hour plant on turn-key basis with your best price and delivery including full technical specifications, literature, drawings 
and best export price.
Provided you can offer a good solution there is a chance of selling many more such plants for the local councils of the same 
country, so this is an excellent chance for you to join forces with our company for market penetration with your products in 
Europe.
1. TS100 model with dry scrubber system
2. YD150 with a wet scrubber system

 

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 


Incinerator burn medical and bio waste


Incinerator burn medical and bio waste

Items/Model

TS100(PLC)

Picture

 

Principle

Medical  Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V/380V

Power

0.7Kw

Oil Infection (kg/hour)

average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

10Meter

Chimney Sort

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 


Incineration plant System of 150kg/hr on LPG


Incineration plant machine of 150kg/hr On Lpg

Items/Model

TS150(PLC)

Picture

 

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1500L

Internal Dimensions

150x100x100cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Oil Infection (kg/hour)

Typical 24.2(D.O)

Gas Consumption (m3n/hour)

Typical 21.3(LPG)

Infection Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Form

Stainless Steel

1st.

2020-07-09

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time


2.0 Sec.

HICLOVER – Medical Environmental, WWW.HICLOVER.COMWaste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Gross Weight

8500kg

External Dimensions

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com 
Nanjing Clover Medical Technology Co.,Ltd.


300x160x190cm


 


Wet scrubber for incinerators


having waste out of production procedure which is having very fine/powder substance with moisture of 40%. Will this system appropriate for this application.  For power waste, wet plus proposal scrubber system.

Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust.

 

Measure 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator. Function: cooling, remove dust, remove fog(from water).

 

 

If waste is Acidic substance, add Caustic soda to the water and cost a litter higher than without Caustic soda.

If also wet scrubber, request build cooling (recirculating water) at nearby website.  Recirculating water pool and Sludge sedimentation at bottom, wash Sludge regular.

 


HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



 

2020-07-08


HS Code for waste incinerator 84178050


HS Code for waste incinerator 84178050

Item

Specification

Model

TS100 PLC

Main Product List per 01 set

Main Combustion Chamber

 

Secondary Combustion Chamber

 

Smoke Filter Chamber

 

Incinerator PLC Control Case

 

Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

 

Italy oil/gas burner: 02 units

 

Oil Tank (if Petroleum fuel): 200Liters

 

 

Optional Component: Stainless Steel Wet scrubber

municipal waste incinerators RWANDA


RWANDA medical waste incinerator Available

HICLOVER – Medical Environmental, WWW.HICLOVER.COM, Waste Incinerators, 
Medical Waste Incinerator,Pet Animal Cremation, Solid Waste Incinerators

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator(Containerized Mobile Incinerator)

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.



 


China incinerator supplier


china incinerator supplier

We provide single combustion chamber, dual glazing chambers, three combustion chambers and multi-combustion chambers waste incinerators for lab, clinic, hospital, medical centre, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc..