Biomedical waste management ppt


Items/Model

TS50(PLC)

Picture

Principle

Medical Waste Incineration,Double chamber incinerator

Burn Rate

50-100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Electricity

0.7Kw

Oil Infection (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Infection Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

5Meter

Chimney Sort

Steel

1st.

800℃–1000℃

2nd.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.


PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

No

Description

Specification

 

1

Sort

Double Chamber (Primary + Secondary Type Controlled Air Pyro Lytic Biomedical Waste Incinerator with Chimney Arrangement

yes

Two

Incineration Capacity

>50 Kg. Per hour

Yes, 50-100kgs/hour

3


Duration of Use

According to operational requirements

Typical 10years

4

quantity of Chambers

02 No.s

yes

Number of Burners each Chamber

01 No.s

yes

5

Total burners per incinerator

02 No.s

yes

6

Primary Chamber Operation Temperature

Max. 900 Degree Celsius

800-1000 Degree Celsius

7

Secondary TemperatureOperation Temperature

Max. 1075 Degree Celsius

1000-1200 Degree Celsius

Design Temperature for both chambers

Max. 1500 Degree Celsius

1750 Degree Celsius

8

Incinerator Efficiency

98-99 %

yes

9

Refractory Materials

High Alumina Refractory

High Alumina Refractory and firebrick

10

Refractory Sort

Castable kind

yes

11

Ash Removal

Manual Removal Drawer Tray

yes

12

Material of Construction of Chamber

IS 2062

Q235, like IS2062

13

Form of Burner Used

Completely Automated Electrically operated burner together with Head with photo cell for flame supervision Nozzle and Electrode

yes

Link hoses, Ignitor, Pump Fan & Cabling System

yes

14

Qty.

01 No.

 

15

Power

230 / 440 V According to availability at end user

220-240V

16

Electrical Cabling

Within battery limitations

Standard 3Meter

17

Refractory

 

18

Sort

Castable Sort

yes

19

Anchor Fasteners

AISI 316

Firebrick made,none anchors. S.S fiber 446

20

Coating on Anchors

Parafin

not one

21

Alumina Percentage

40-60 %

Above 60%

22

Density

2.1 g/Cubic cm

3-3.5 g/Cubic cm

23

Service Temperature Max.

1500 Deg. Celsius

1750 Deg. Celsius

 

Insulating Castable

 

24

Sort

Castable

High alumina ceramic fiber Insulation

25

CCS at 110 Grade

35-45 Kg /Sq.. Cm.

Not one parameter

26

Grain Size

5 Millimeter

Not one parameter

27

Density

1.2 gm / cm3

220kg/m3

28

Service Temperature

1350 Degree C

1260 Degree C

 

Control Panel

 

29

Degree of Ingress Protection

IP 55

yes

30

Tool MOC

SS 304

yes

31

Tool

Cabinet with Observation Glass and PLC Programmer

yes

32

Chimney

 

33

MOC

IS 2062

yes

34

Height

According to necessity

5 meter

3536

Total Space RequirementCompleted with Civil and Electrical

Maximum 5 Mtr. X Mtr. Work

yes

2021-02-23

34

Height

As per requirement

5 meter

35
36

Total Space Requirement
Completed with all Civil and Electrical

Maximum 5 Mtr. X 5 Mtr. Work

yes


 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23


Hospital waste Overall waste incinerator



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

The equipment proposed Will be an incinerator specialised for Medical Wastes.  

Nanjing Clover Medical Technology Co.,Ltd.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )


100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-10-07

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-10-07


waste incinerator manufacturer china


waste incinerator manufacturer china

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.

Smallest Waste Incinerator for PPE waste face mask glove Squander


Smallest Waste Incinerator for PPE waste face mask glove waste
Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney
ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications

Model

YD-10

Picture

 

Feed Capacity

Average 20 kgs per feeding

Burning Rate

Average 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Gas

Diesel Petroleum

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

Ave. 4.2 Kgs/Hour

External Dimensions

Dia.100 x 130cm (mainbody)

Internal Dimensions

Dia.50 x 80cm

Waste combustion chamber

200Liters

Oil Tank Capacity

100 Liters

Door Opening

35 x 35cm

Chimney

1.5M

Gross Weight

Ave.400kgs

Chamber Material

Refractory Concrete&Ceramic Fiber 

Max.

42,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

14000C

Burning efficiency

>98%

Waste Lower Calorific Power

3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 


Medical Waste Management System


Items/Model

TS50(PLC)

Picture

Principle

Medical Waste Incineration 

Burn Rate

50-100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Gas Flue Washing System incineration of medical waste

Feed Mode

Manual

Voltage

220V

Power

4.0 Kw

Oil Infection (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Infection Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

15Meter

Chimney Sort

S.Steel

1st.

1000℃-1200℃

Residency Time

2.0 Sec.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

For additional creature incineration

Nanjing Clover Medical Technology Co.,Ltd.

ü BIO-Medical/Hospital Waste Incinerator Modular Package Form, free standing unit consisting of (Primary chamber, Secondary Chamber, stake, controller and gas flue washing machine ) how can a waste to energy plant work

ü Diesel Oil And GAS Fired Burners (Dual)

ü Stainless Steel stack for strength

ü Burning capability: 50-60kgs of waste ruined per hour. 

ü Average ash residue: 3 to 4 percent

ü Operating Temperature 850°C to maximum 1320°C or better:

ü Upto 1150°C in a secondary chamber

ü Residency Time in Secondary Chamber of two minutes

ü Thick refractory liner & insulation more than 200mm rated to 1600°C in primary chamber retains warmth, increasing efficacy

ü Separate doors for loading and ash removal

ü Loading door for maximum operator protection for immediate heat exposure

ü Burner with temperature activated modulating control

ü Dual HT Thermocouples: Allow independent control of Primary and secondary temperatures through the control panel

ü Stress mill with modulating air controller

ü Stainless Steel cladding for optimum heat retention, cool touch and hygiene controller

ü Rapid, efficient and complete medical waste disposal

ü Safe use manage

ü high-quality liner and insulatio,management of hazardous waste

ü PLC touch screen, double burner controller, preset burn times and blower

ü Temperature monitoring

ü Programmable digital temperature controls for total combustion

ü Secondary burner temperature activated controlling control

ü Fast pre-heat and persistent high temperature functionality

ü Heavy duty lock: Made by us to ensure tight locking chamber with no air openings. Simple to open and shut

ü Low energy intake rates

ü 2 efficient high efficiency burners for better fuel saving to save a hour fuel burning price.

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.


PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2021-02-23

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23


Effect of biomedical waste on human health


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Equipment Technical Specifications

Model

TS30S

Picture

 

Feed Capacity

78 Liters for Main chamber

Burning Rate

Typical 30 kgs Each hour

Burning Time Each Feed

0.5 hour

Voltage

220V

Power

0.5Kw

Gas

Diesel oil

Burner

Diesel Oil Burner, 2 sets

Feed Mode

Manual

Fuel consumption (Oil)

Typical 8 Kgs/Hour

External Dimensions

90 x 90 x 150cm (main body)

Internal Dimensions

Dia.50 x 40cm(Primary Chamber)

Waste combustion chamber

78Liters

Article Combustion Chamber

50Liters

Oil Tank Capacity

100 Liters

Door Opening

25 x 25cm

Chimney

3.0M

Gross Weight

1200kgs

Chamber Material

Refractory Concrete 

Max.

80,000Kcal/Hr.

Operation Technical Specifications

Chamber fever

8000C -10000C

Chamber Anti-Rate

13500C

Residency time

0.5 Sec.

Burning efficiency

>98 percent

Waste Lower Calorific Power

ways of disposing solid waste

3000Kcal

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For additional animal incineration

consequence of biomedical waste on human health


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations.
“The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle. 

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room2021-02-21


Incinerator type of pyrolytic medical waste incinerator capacity


Including:Incinerator: Structure to be specified

Together with the following technical information:

1.      1 pharma solid waste incinerator unit containing 2 combustion chambers and predicated on steel base with scrubbing

system.

2.      Working hour /day: minimum 10 hours/day. Capacity: Approximated 150 kg/hr. Over 10 hrs.

4.      Wastes characteristics:

·         BULK density: 70 — 100 pound / bm³.

·         Calorific value: 2000-3000 kcal / hr.

·         Moisture content: 20-30%by weight.

·         Ash content: two — 8 percent by weight.

·         Plastic content: 15-20 percent by weight.

5.      Two combustion chambers.

6.      Operating temperatures:

·         First chamber: less than 700 – 800 °c.

·         Second chamber: less than 1200 °c (during steady operation).

7.      The burners should be automatically switched off if some of the combustion chambers is open.

8.      The burners of the first and second combustion chambers are selected for burning gas oil (light fuel).

9.      Automatic loader and unloader to be provided.

10.     Exhaust gases should be comply with International Environmental code and requirements.

– A receiving cage for biomedical waste;

– A combustion chamber using a chimney using a filter to keep the ash;

Chimney segment: about 300 cm; With a minimum height of 6 m

Door dimensions: approximately 50×60 cm

Supplied using a 500 liters gas tank along with all required accessories for installation.
The mark to be given
Capacity: 20-50 pound / hour
Fireplace: 4 to 6 meters ;


Incinerator Model TS10


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Incinerator Model TS10 PLC, Overview

 


This model Building is dual/double combustion Room with 02 Components oil burner, batch load incineration Gear. 

Items/Model

TS10(PLC)

 

 

 

Picture

 

Burn Rate

Average 10 kg/hour

Feed Capacity

Average 20kg/feeding

Control Mode

Programmable Logic Controller(PLC) Panel

Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

typical 8.4kg/hour

Gas Consumption (m3/hour)

typical 10.1m3/hour

Temperature Monitor

Yes

Temperature Protection

Yes

Oil Tank

100L

Feed Door

30x30cm

Chimney

5 Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

1500kg

External Dimensions

140x90x120cm


Combustion Chamber Volume (m3) 1.25m3
Gas Retention 2-3 Seconds
Operational Temperature Minimum 850°C for the primary chamber; min 1100
oC for the secondary chamber.
Metal Thickness 4mm
Average Ash Residue (%) 3%
Dimensions (l, w, h) 1.85m x 1.11m x 8.10m
Shipping Weight (kg) Up to 6 tonnes- anything less not acceptable
Fuel Consumption 13 – 18 liters per hour
Burn Rate* up to 100kg per hour
Thermostatic Device Included
Door Size (m) 0.64m x 0.54m minimum for ease of loading
Stack The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account. Point for the measurement of emissions shall be provided.
The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.
Diesel Tank A reinforced steel tank with a capacity of min 500 litres. The diesel tank shall come complete with a stand and connection valves.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

2020-09-16

 