Animal Crematory Design for Pets Cremation Business Model A1500


Model

A1500(Movable platform & Automobile.

Picture

 

Burning Rate

Average 50 kgs/hour

Feed Capacity

Average 150 kgs/feeding

Main Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Gas Form

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 34 kg/hour

Gas Consumption (Natural gas )

Average 41 m3n/hour

Internal Dimensions

150 x 100 x 96cm (primary room )

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Sort

Stainless Steel

Equipment Gross Weight

7500 kgs

Operation Technical Specifications

Main Chamber Temperature

800℃–1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98 percent

Waste Lower Calorific Power



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

3000Kcal

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

2020-11-04

 

2020-11-04


N.D. could receive Ebola waste from Calif.


FARGO, N.D. — California health officials have given notice that North Dakota is one of six states that could receive Ebola medical waste in the event the state has any material to incinerate.

In a notice posted last week, the California Department of Public Health listed North Dakota as one of six states where California sends medical waste to be incinerated when onsite disposal is not available at medical centers.

Healthcare Environmental Services Inc., located at an industrial park at 1420 40th St. N. in Fargo, operates a medical waste incinerator that also accepts waste from other locations.

Calls to Healthcare Environmental Services on Tuesday afternoon were not returned.

The company is owned by Sanford Health. A Sanford spokeswoman said it could not immediately comment on the possible incineration of Ebola waste from California at the Fargo facility.

So far, California has no known Ebola cases, according to the state health department, which spelled out its interim guidelines for safe handling of medical waste in an alert to providers and others.

In another development, public health officials are monitoring two North Dakota residents who recently returned from countries in West Africa that are battling the Ebola epidemic.

Neither of the two residents is running a temperature or showing any symptoms of an Ebola infection, which can include diarrhea, joint and muscle aches and abnormal bleeding.

“They’ve just recently traveled to the area,” said epidemiologist Michelle Feist of the North Dakota Health Department. “They pose no risk to the community.”

Health officials are not releasing information about where the two people reside.

Public health officials in Minnesota and South Dakota also are monitoring residents in those states who have recently visited Guinea, Liberia or Sierra Leone in West Africa, where an outbreak of Ebola has killed about 5,000.

State health officials are contacted by the Centers for Disease Control and Prevention when someone is entering the United States from those countries through five major international airports.

“We are doing monitoring,” said Sam Brungardt, a public information officer for the Minnesota Health Department.

On Monday, Minnesota health officials announced that they were monitoring one resident who had traveled to West Africa, but the list of people to monitor is growing.

“It has grown, and it will continue to grow as we get reports from the CDC,” Brungardt said. “There’s people who are returning from these three West African countries every day.”

So far, none of those being monitored for signs of fever with twice-daily temperature checks show any sign of infection, he said.

As a precaution, however, they will continue to be checked during the 21-day observation period, generally regarded as the incubation period for the Ebola virus.

South Dakota health officials also are monitoring someone who recently returned from West Africa, but is not showing symptoms.

by: http://bismarcktribune.com/news/state-and-regional/n-d-could-receive-ebola-waste-from-calif/article_10e0e242-5f2c-11e4-8ff8-8ba8bab48ce3.html


The cost of a small incinerator



Medical Waste Incinerator Capacity: Typical 50-100 kgs Each hour

Items/Model

TS50(PLC)

Picture

 

Principle

Medical Waste Incineration 

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 100kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Infection (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Infection Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

Gross Weight

4500kg

External Dimensions

230x130x155cm

Optional Part: Stainless Steel Wet scrubber

HICLOVER Incinerator/Parts Range


Main Feature

Medical Waste Incinerators


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Nanjing Clover Medical Technology Co.,Ltd.

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)


TS500(PLC)

Burn Speed (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm



Sudan Kassala state and we are working on installing an incinerator for Girba hospital in Girba locality.
 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

2020-10-28

 

2020-10-28


HICLOVER Top Feeding Door Waste Incinerators


HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke




HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 


Controlled air medical waste incinerator designed for incineration of bio-medical waste


Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION


Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Biomedical waste management ppt


Items/Model

TS50(PLC)

Picture

Principle

Medical Waste Incineration,Double chamber incinerator

Burn Rate

50-100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Electricity

0.7Kw

Oil Infection (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Infection Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

5Meter

Chimney Sort

Steel

1st.

800℃–1000℃

2nd.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.


PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

No

Description

Specification

 

1

Sort

Double Chamber (Primary + Secondary Type Controlled Air Pyro Lytic Biomedical Waste Incinerator with Chimney Arrangement

yes

Two

Incineration Capacity

>50 Kg. Per hour

Yes, 50-100kgs/hour

3


Duration of Use

According to operational requirements

Typical 10years

4

quantity of Chambers

02 No.s

yes

Number of Burners each Chamber

01 No.s

yes

5

Total burners per incinerator

02 No.s

yes

6

Primary Chamber Operation Temperature

Max. 900 Degree Celsius

800-1000 Degree Celsius

7

Secondary TemperatureOperation Temperature

Max. 1075 Degree Celsius

1000-1200 Degree Celsius

Design Temperature for both chambers

Max. 1500 Degree Celsius

1750 Degree Celsius

8

Incinerator Efficiency

98-99 %

yes

9

Refractory Materials

High Alumina Refractory

High Alumina Refractory and firebrick

10

Refractory Sort

Castable kind

yes

11

Ash Removal

Manual Removal Drawer Tray

yes

12

Material of Construction of Chamber

IS 2062

Q235, like IS2062

13

Form of Burner Used

Completely Automated Electrically operated burner together with Head with photo cell for flame supervision Nozzle and Electrode

yes

Link hoses, Ignitor, Pump Fan & Cabling System

yes

14

Qty.

01 No.

 

15

Power

230 / 440 V According to availability at end user

220-240V

16

Electrical Cabling

Within battery limitations

Standard 3Meter

17

Refractory

 

18

Sort

Castable Sort

yes

19

Anchor Fasteners

AISI 316

Firebrick made,none anchors. S.S fiber 446

20

Coating on Anchors

Parafin

not one

21

Alumina Percentage

40-60 %

Above 60%

22

Density

2.1 g/Cubic cm

3-3.5 g/Cubic cm

23

Service Temperature Max.

1500 Deg. Celsius

1750 Deg. Celsius

 

Insulating Castable

 

24

Sort

Castable

High alumina ceramic fiber Insulation

25

CCS at 110 Grade

35-45 Kg /Sq.. Cm.

Not one parameter

26

Grain Size

5 Millimeter

Not one parameter

27

Density

1.2 gm / cm3

220kg/m3

28

Service Temperature

1350 Degree C

1260 Degree C

 

Control Panel

 

29

Degree of Ingress Protection

IP 55

yes

30

Tool MOC

SS 304

yes

31

Tool

Cabinet with Observation Glass and PLC Programmer

yes

32

Chimney

 

33

MOC

IS 2062

yes

34

Height

According to necessity

5 meter

3536

Total Space RequirementCompleted with Civil and Electrical

Maximum 5 Mtr. X Mtr. Work

yes

2021-02-23

34

Height

As per requirement

5 meter

35
36

Total Space Requirement
Completed with all Civil and Electrical

Maximum 5 Mtr. X 5 Mtr. Work

yes


 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23


Hospital waste Overall waste incinerator



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

The equipment proposed Will be an incinerator specialised for Medical Wastes.  

Nanjing Clover Medical Technology Co.,Ltd.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )


100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-10-07

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-10-07


waste incinerator manufacturer china


waste incinerator manufacturer china

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.