HICLOVER Top Feeding Door Waste Incinerators


HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke




HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 


Medical Waste Incinerator for covid19 waste 100-150-300-500kgs per hour


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

● Double Combustion Chambers
All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. 
● Containerized Mobile Incinerators
The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck. 
● Family Pets Dog&Cat Cremation
Special design with movable platform, combustion chamber material and custom made for pets crematory business. 
● Installation and Commissioning
Clover’s engineers install,train for most of the region and free-cost train in our factory. 


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Optional Optional Optional Optional

Smoke Wet Scrubbers

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Sort

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm


hospital incinerator ash
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

450x210x300cm

 


Medical Waste Incineration Model TS20(PLC) Wet Scrubber (Water Spary tower)


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model

TS20(PLC)

Picture

 

Principle

Medical Waste Incineration 

Burn Rate

Average 20 kg/hour

Feed Capacity

Average 40kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

210L

Internal Dimensions

65x65x50cm

Secondary Chamber

110L

Smoke Filter

Wet Scrubber (Water Spary tower)

Feed Mode

Manual

Voltage

380V

Power

5Kw

Oil Infection (kg/hour)

7.8–16.3

Gas Consumption (m3/hour)

8–15.7

Infection Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

100L

Feed Door

45x40cm

Chimney

5Meter

Chimney Sort

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4000kg

External Dimensions





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

160x110x130cm(Incinerator)

 


Integrated Solid Waste Management System medical waste incinerator


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Ability: Typical 300 kgs per hour

Model

YD–300

Picture

 

Burning Rate

Typical 300 kgs/hour

Feed Capacity

Average 500 kgs/feeding

Primary Combustion Chamber

2400 Liters

Secondary Combustion Chamber

1200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Wet Scrubber System(3 Part Form )

Feed Mode

Manual

Voltage

380V

Power

12.0 Kw

Gas Form

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Typical 33kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

220 x 110 x 100cm (primary Room )

External Dimensions

260 x 220 x 420cm (without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity(if Petroleum fuel)

500 Liters

Door Opening

90 x 110cm

Chimney Length

10.0 Meters

Chimney Sort

Stainless Steel

Equipment Gross Weight

14000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power



3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Pathological waste: organs, cells, surgical specimens, physiological fluids removed during surgery or autopsy. 

 


Small Medical Waste Incinerator 2 combustion chambers with scrubber


Small Medical Waste Incinerator 2 combustion Room with scrubber for Virus medical waste

On-Site Incineration Solution‎

Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, 
and medical research facilities. These wastes include both infectious (“red bag”) 
medical wastes as well as non-infectious, general housekeeping wastes.

1st. Chamber Temperature
Items/Model
Chimney
220V
 
Yes
100L or More(Optional)
Feed Capacity
Secondary Chamber
0.5Kw
Average 16
Temperature Protection
Power
Feed Door
Four Digital Screen
Smoke Filter Chamber
Internal Dimensions
330L
175x120x140cm
Stainless Steel
55x50cm
Burn Rate
Temperature Monitor
Average 60kg per feeding
Oil Consumption (kg/hour)
2.0 Sec.
5Meter or More(Optional)
Chimney Type
External Dimensions
Average 11.7
Gross Weight
Residency Time
4000kg

Items/Model

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-27


Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 Squander


Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 


Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower


Model

YD-150

Burning Rate

Typical 150 kgs/hour

Feed Capacity

Average 300 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Gas Form

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17–36 kg/hour

Gas Consumption (Natural Gas)

11–36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary Room )

External Dimensions

240 x 170 x 380cm (without chimney)

Infection Monitor

Yes

Oil Tank Capacity(if oil Gas )

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

before start the 2nd burner, full close all air valve on the 1st chamber. other operation keep same. 
reason: at the first 10-20 min burnning the plactic waste, deflagration combustion in the chamber. 
after 10-20 min, gradually increase air injection by air valve on the 1st chamber.
meanwhile, proposal 20-30 min burnning of the 1st chamber, stop the 1st burner(stop fire only, the fan inside the burner 
still working), let the plastic burn itself(Spontaneous combustion) to save diesel oil.
a small waste to energy project to turn municipal solid waste 

7500 kgs

Model

YD-150

Main Product List

Primary Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Smoke Filter Chamber(Dry Scrubber)

 

Incinerator Control Case(PLC Auto.Type)

 

Chimney:10.0Meters

Chimney (upgrade to Stainless Steel, free Price )

 

Italy oil/gas burner: 02 sets

 

Oil Tank (if oil fuel): 300Liters

 

Optional Part:

Stainless Steel Wet scrubber(Cooling Spray Coating )

into electricity. The project is to cater for a local council with a population of around 60,000 people and will serve as a 
pilot project. If project is successful than other such plants will be installed in other towns and villages. The villages 
will all cater for the MSW in their locality instead of a central large incineration plant to cate for the whole county.for a 7 ton per 
hour plant on turn-key basis with your best price and delivery including full technical specifications, literature, drawings 
and best export price.
Provided you can offer a good solution there is a chance of selling many more such plants for the local councils of the same 
country, so this is an excellent chance for you to join forces with our company for market penetration with your products in 
Europe.
1. TS100 model with dry scrubber system
2. YD150 with a wet scrubber system

 

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 


Incinerator burn medical and bio waste


Incinerator burn medical and bio waste

Items/Model

TS100(PLC)

Picture

 

Principle

Medical  Waste Incineration Treatment

Burn Rate

Average 100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V/380V

Power

0.7Kw

Oil Infection (kg/hour)

average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

10Meter

Chimney Sort

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.