Two Chamber Medical Waste Incinerator


Basic Info.

Model NO.:tempreture of the stoker moving grate incinerator
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs big medical incinerators, big scale medical waste incinerator, bio medical incenarator manufacturer in china, bio medical waste incinerators manufacturers china, per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator


Basic Info.

Model NO.:50 kgs per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc. 
The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal manufacturers of medical incinerator, manufacturers of the incineration of hazardous waste, manufacturers on medical incinerators, manufacturers waste incinerators, with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion. 

Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell. 
The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation. 
In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Items/Model TS50(PLC)
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree -1200 degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm
 

Small Scale Incinerator (TS100 PLC)


Basic Info.

Model NO.:TS100 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER
Packing:Full Container
Standard:100kg per hour
Origin:China Nanjing
Production Capacity:1000 Sets Per Year

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and mobile medical incinerators pictures, mobile pet crematorium stove, mobile pet incierators, mobile waste incinerators, mobile waste to energy incinerator sales other Solid waste. The capacity from 10kgs/Hr. To 600kgs/Hr., up to 10ton per day. 

Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. 
* PLC Control Plane for Intelligent operation. 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock.

Feed Capacity 200 kg
Control Mode PLC
Combustion Chamber 1200L
Internal Dimensions 120x100x100cm
Secondary Chamber 600L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 14–28
Gas Consumption (m3/hour) 10–32.2
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 200L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree
Residency Time 2.0 Sec.
Gross Weight 6000kg
External Dimensions 260x150x180cm

Msw Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:nanjing clover medical
Origin:Nanjing

Product Description

It is being recently issued an ordinance by the Ministry of Environment to build incineration plants in the metropolitans which generate more than 10.000kg of medical waste per day. And this implementation is going to start in the beginning of the year 2014. 
Our aim is to build a Medical Waste Incineration Plant in one of the metropolitan cities in Turkey. We have been preparing for the tenders which are going to be held soon by the Metropolitan Municipality. 
We would like to cooperate with a supplier/contractor for building an incineration plant. Would you be able to advise if you devise incineration plants, if yes kindly advise in which part of the world you had worked (built incineration plants). 

Could you also please inform us regarding the following issues: 
– Is it possible to reach an incineration temperature of 1.100° C within the systems which you have been devising? (This is one of the standards for the incineration plants according to the regulations in Turkey). 
– Is it possible to generate electricity and how? 
– If it is possible to generate electricity within the system, what would be the kwh amount of electricity per ton of waste incinerated? 
– What is the period for building the plant? How long would it portable medical incinerators, portable pet cremation, portable trash incinerator, posco krakow incineration plant, post-animal incinerator fuel, take for building a plant and would it depend on the plant capacity as for 1.000kg/hr or 2.000kg/hr? 
– What is the water consumption per incinerated ton? And if there is electricity generation within the system, what would be the amount of water consumption per ton for generating 1 kwh of electricity? 
– Do the plants which you devise have gas cleaning and filtering systems? If already included or can be added, would you be able to advise your prices including the gas cleaning and filtering systems? 
– Would there be a change in the prices if electricity generation can be added to the system? If yes, would you please advise your prices according to this? 
We look forward to your cooperation. 
Thank you in advance for your quickest possible response. (Turkey) 

Que valor tiene un incinerador PARA quemar droga. 

– Que consumo de energí A tiene? ? ? 
– Cuanta contaminació N genera a la ATMó Sfera. 

Saludos y quedo atento. (Chile)

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm