HICLOVER 10-500kgs/Hr.Double Combustion Chambers


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For additional creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )


100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-09-17

300x160x190cm

400x210x300cm

450x210x300cm


TECH SPECS FOR 200KGHOUR INCINERATOR 

The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg 
The Temperatures of combustion: Minimum will be 850oC and max 1400oC
Post combustion: >1100oC.
The Internal diameter of the Chimney: Ø 400mm² and its height: 8 m 
The Volume of the combustion chamber: 1.200 L 
The Dimension of the door for loading in cm: 70×70. 
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. 
* A secondary injection of air to ensure perfect oxygen content. 
A control box ensuring the complete cycle of combustion. 

Fan: 
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. 
Controls and regulations: 
Control box water tight to dust, including: 

* A switch circuit breaker for each engine (ventilators and burners). 
* A timer with adjustable temporization for the regulation of each burner. 
* A regulator with digital watching for the temperature of combustion. 
* A regulator with digital watching for the temperature of post combustion. 
* Electric box.

The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing. 
Process Filtering system: Scruber to be mentioned as optional
Emission Standards Compliance: BS 3316 or equivalent standard
Capacity to treat Plastic: Not less than 40% by weight
The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
The installed incinerator must bear a one year guarantee.
The supplier shall perform an onsite installation of the incinerator.
The technical training of operators will have to be provided and given by a technician from  
the factory; it will consist of curative and preventive maintenance, and the use of machine, etc 
Fence Wire for Incinerator House (Chain Link) should be NOT less than 2.5Meters height.
Waste Storage Bay and Ash Pit drawings attached.
 
This material and equipment must include in the shed of the incinerator: foundation in rubble stone, isolation roofing against humidity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel frame (charpenteen metal); 


HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-17


Best Feeding Door HICLOVER 10-500kgs/Hr.Double Combustion Chambers Waste Incinerators


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER is currently offering a broad selection of medical waste incinerators, designed to provide efficient waste destruction, using best available technologies and environmentally friendly procedure. Due to the secondary room with its 2 minute retention period, our healthcare incinerator range is well suited to process clinical waste.

 

Our products guarantee effective, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste such as pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies, Medication Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Form

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


Type of waste: medical and industrial (solid and semi solid hazardous)
Type of waste : Bio-medical & Hazardous (Solid and Semi Solid) 
If you are a hospital then Please also tell how many bedded hospital : No aren’t a hospital 
Quantity of waste generated per day in kg : 6000 kg
Duration C incinerator will be used per day :1 C 16 hours 
Approximate moisture content: 47 to 53%
Availability of power and type : 3 Phase, 440 Volts
Details of space available : Min. 10000 Sq.  ft.
Do you require an automatic loading system? Depends if it is a continuous burning or interval burning.
How soon do you require the system to be delivered? 8 weeks
Whether the location is a coastal area : No
An other specific requirements: Automatic PLC Control System.
Burning Rate: 500kg/hour
Volumetric capacity Primary Chamber: 500kg
Burner Type: Diesel Operated
Burning Process: Continuous

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-16


General waste incinerator, dual chamber (primary & secondary)


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Items/Model

TS30(PLC)

Picture

 

Burn Speed

Typical 30-50 kg/hour

Feed Capacity

Typical 60kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Electricity

1.0 Kw

Oil Consumption (kg/hour)

Typical 13.3

Gas Consumption (N.G, m3n/Hour)

***

Gas Consumption (L.P.G, m3n/Hour)

***

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

600L 

Feed Door

55x50cm

Chimney

5Meter 

Chimney Sort

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

3000kg

External Dimensions




General waste incinerator, dual chamber (primary & secondary), average waste production 200kg/day, nominal burning rate 25 kg/hr (200 kg per 8 hours per day). 380/400 Vac ±10%, 50Hz ±3%, 3Ph or 220/240Vac ±10%, 50Hz ±3%, 1Ph. Diesel fuel storage capacity of the unit for 5 working days in 8 hours each. Minimum life expectancy of 10 years. Meet EU CEC 2000, US AP42, EPA 1995 standards of emissions and operations or equivalent.General waste incinerator, dual chamber (primary & secondary), average waste production 125kg/day, nominal burning rate 15.63 kg/hr (125 kg per 8 hours per day). 380/400 Vac ±10%, 50Hz ±3%, 3Ph or 220/240Vac ±10%, 50Hz ±3%, 1Ph. Diesel fuel storage capacity of the unit for 5 working days in 8 hours each. Minimum life expectancy of 10 years. Meet EU CEC 2000, US AP42, EPA 1995 standards of emissions and operations or equivalent.General waste incinerator, dual chamber (primary & secondary), average waste production 75kg/day, nominal burning rate 9.4 kg/hr (75 kg per 8 hours per day). 380/400 Vac ±10%, 50Hz ±3%, 3Ph or 220/240Vac ±10%, 50Hz ±3%, 1Ph. Diesel fuel storage capacity of the unit for 5 working days in 8 hours each. Minimum life expectancy of 10 years. Meet EU CEC 2000, US AP42, EPA 1995 standards of emissions and operations or equivalent.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

175x120x140cm

 


Incinerator Model TS10


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Incinerator Model TS10 PLC, Overview

 


This model Building is dual/double combustion Room with 02 Components oil burner, batch load incineration Gear. 

Items/Model

TS10(PLC)

 

 

 

Picture

 

Burn Rate

Average 10 kg/hour

Feed Capacity

Average 20kg/feeding

Control Mode

Programmable Logic Controller(PLC) Panel

Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

typical 8.4kg/hour

Gas Consumption (m3/hour)

typical 10.1m3/hour

Temperature Monitor

Yes

Temperature Protection

Yes

Oil Tank

100L

Feed Door

30x30cm

Chimney

5 Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

1500kg

External Dimensions

140x90x120cm


Combustion Chamber Volume (m3) 1.25m3
Gas Retention 2-3 Seconds
Operational Temperature Minimum 850°C for the primary chamber; min 1100
oC for the secondary chamber.
Metal Thickness 4mm
Average Ash Residue (%) 3%
Dimensions (l, w, h) 1.85m x 1.11m x 8.10m
Shipping Weight (kg) Up to 6 tonnes- anything less not acceptable
Fuel Consumption 13 – 18 liters per hour
Burn Rate* up to 100kg per hour
Thermostatic Device Included
Door Size (m) 0.64m x 0.54m minimum for ease of loading
Stack The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account. Point for the measurement of emissions shall be provided.
The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.
Diesel Tank A reinforced steel tank with a capacity of min 500 litres. The diesel tank shall come complete with a stand and connection valves.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

2020-09-16

 

2020-09-16


HICLOVER Top Openning Door Waste Incinerators


Top Openning Door Waste Incinerators

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-09-02

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

200L

Nanjing Clover Medical Technology Co.,Ltd.

300L





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

500L

500L

 

2020-09-02


Best Feeding Door Solid Waste Incinerators HICLOVER


HICLOVER Top Feeding Door Waste Incinerators

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke



parts of an incinerator
physical method of disposing hazardous chemical waste
portable incinerators types
proper ways of waste disposal in the community
questionnaire to ask about incinerators for collection of data

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 


HICLOVER Top Feeding Door Waste Incinerators


HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke




HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 


High Temperature Incineration Procedure HICLOVER YD30


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Model YD-30 
Burning Rate  average 30 kgs/hour
Feed Capacity average 40 kgs
Paimary Combustion Chamber 200 Liters
Secondary Combustion Chamber 100 Liters
Mix Combustion Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil
Burner Italy Original
Oil Consumption (Diesel Oil) average 13.3 kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 80 x 50 x 50cm (paimary chamber)
External Dimensions 125 x 90 x 180cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 60 Liters
Door Opening 40 x 40cm
Chimney Length 1.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 1000 kgs



what is incineration
what is the cost of building incenerator in uganda
3d drawing of incinerator

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator