Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Composting vs. Waste-to-Energy: The Politics Of Green Waste
In Tulsa, Oklahoma, green waste is very much on the political agenda. According to Tulsa World, the city’s trash board voted this week to pursue a plan to collect and incinerate it rather than invest in an active composting facility. Proponents of the composting plan are deeply disappointed by the vote.
City Councilor Karen Gilbert says, “That [vote] sets us further back from the original plan of having an active composting, mulching facility,” Gilbert said. “It’s frustrating that we start off with an investment, but then we don’t follow through with the priority of that investment.”
Those in favor of the incinerator approach complain that the city can’t afford the cost of the proposed composting facility and that is costs too much money to separate out the green waste from the rest of the city’s trash. Doesn’t it seem as though the situation in Tulsa is a microcosm of the entire “global warming/climate change” debate going on around the globe?
Green waste consists of two components: yard waste, such as leaves and grass clippings, and food waste. Disposing of them requires different strategies but taken together, they account for a significant proportion of all the waste going into US landfills every year.
According to GreenWaste.com, about 75% of solid waste is recyclable, but at present only about 30% actually gets recycled. 21.5 million pounds of food waste gets sent to our landfills every year. If that food waste were composted, the reduction in harmful emissions into the atmosphere – mostly methane – would be equivalent to taking 2,000,000 cars off the roads in America.
In Washington State, a local prison is vermicomposting all its food waste and saving about $8,000 a year in disposal costs. The compost then gets spread on the prison gardens to help grow food for the kitchen. At North Carolina State University, an ambitious program to collect and compost empty pizza boxes is on track to process more than 370 tons of the containers in its first year. And in Massachusetts and Seattle, new laws mandate composting of food wastes.
In Sweden, 99% of all trash is recycled, composted or burned. Sweden does not have the amount of open available land needed for large landfills. It also does not have the abundance of natural resources that the United States does. So it operates a number of large incinerators that provide electricity and heat for government buildings. Critics say that burning only adds pollutants to the atmosphere, but that nation’s political leaders maintain that modern technology removes virtually all of the harmful emissions and the electricity generated goes a long way towards meeting Sweden’s power requirements.
The best conclusion to draw from all this is that local needs will govern how trash – particularly green waste – gets handled by various communities. There is no “one size fits all” solution. One could argue that Tulsa is taking the easiest way out and looking only at short term costs versus long term benefit. But the real answer is provided by Göran Skoglund, an official with the municipal power facility in Helsingborg, a city in southwest Sweden. He says he hopes the supply of waste to keep the city’s incinerator going will disappear. “This sounds strange…[but] that would be great for this planet. It’s not sustainable producing the amounts of garbage that we do.”
And that’s the take away from this story. Ultimately, it is not about burning vs. composting vs. recycling. In the end, it is about reducing the amount of waste that people generate. That’s where the focus of the political debate about waste products should be.
HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers
|
|
Items/Model |
TS100(PLC) |
TS150(PLC) |
TS300(PLC) |
TS500(PLC) |
Burn Rate (Average) |
100 kg/hour |
150 kg/hour |
300 kg/hour |
500 kg/hour |
Control Mode |
PLC Auto. |
PLC Auto. |
PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L |
2000L |
3000L Internal Dimensions |
120x100x100cm |
150x100x100cm |
170x120x100cm |
210x120x120cm Secondary Chamber 600L |
750L |
1000L 1500L Smoke Filter Chamber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Dry Scrubber |
Feed Mode |
Manual Manual Manual |
Manual |
Voltage |
220V |
220V |
220V |
220V Power |
1.38Kw |
1.69Kw 2.57Kw 4.88Kw |
Diesel Oil Consumption (kg/hour) |
Ave.20.4 Ave.24.2 Ave.33 |
Ave.44 |
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 |
Ave.52.8 |
Infection Monitor
Yes |
Yes |
Yes |
Yes |
Temperature Protection |
Yes |
Yes |
Yes |
Yes |
Oil Tank |
200L |
300L |
500L |
500L |
Feed Door |
80x60cm |
80x60cm |
|
|
Chimney |
10Meter |
10Meter |
14Meter |
14Meter |
Chimney Form |
Stainless Steel |
Stainless Steel |
Stainless Steel |
Stainless Steel |
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
2nd. Chamber Temperature |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
1000℃-1200℃ |
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
Gross Weight |
6000kg |
8500kg |
11000kg |
16000kg |
External Dimensions |
260x150x180cm |
300x160x190cm |
400x210x300cm |
450x210x300cm |
|
|
|
|
|
|
2020-07-27 |
Three Combustion Chambers(Optional) |
3 Ranked for high risk waste |
Pet Cremation Equipment |
For Pet(small/big) Cremation Business |
Animal Incineration Equipment |
For other animal incineration |
General Waste Incinerator |
For MSW |
Mobile Incinerator(Optional) |
Small-Middle scale, cellular function by |
1. ) Wheel |
2.) DC-Power Trolley |
3.) Containerized |
Wet Scrubber for Smoke Filter(Optional) |
1. ) 1 Section Wet Scrubber |
2.) 3 Fragrant Wet Scrubber |
1 Section Wet Scrubber |
S.S304 Cooling Spray tower |
3 Sections Wet Scrubber |
1.) S.S304 Dust Scrubber |
3.) Front/Side Manual Loading |
2.) Top Feeding Door(Optional) |
3.) Auto. Feeding Door(Optional) |
3rd Combustion Chamber(Optional) |
|
Stainless Steel Main Body(Optional) |
S.S201 or S.S304 |
Control Model |
1.) Electric control box(Semi-automatic) |
2.) PLC Auto.control box(Automatic) |
|
Light Weight Upgrade(Optional) |
|
W2E(Waste to Energy)(Optional) |
Hot Water(Non-drinking water) |
Fuel Burner |
Italy Baltur Brand |
4.) Both D.O and N.G/LPG(not 2in1 burner, swap burner kind ) |
Temperature Thermocouple |
1.) K Type,Stainless Steel 1300(Standard) |
2.) K Form,Corundum 1300(Optional) |
3.) S Form,Platinum Rhodium 1600(Optional) |
Control Case Material |
1.) Steel (Conventional ) |
2.) Stailess Steel(Optional) |
|
Chimney/Stack |
1.) Stailess Steel (Standard) |
2.) Steel(Optional) |
3.) Length(Optional) |
4.) Thickness(Optional) |
|
400x210x300cm |
450x210x300cm |
Email: [email protected]
2020-07-27
incinerator for medical waste
incinerator for medical waste.Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.). a diesel fired medical waste incinerator with a capacity of 300Kg/hr. to be installed at a waste disposal site away from populated areas.
Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion.Incinerator with Oil Burner .
Require Quantity – 1 complete Unit / Set
Type of Materials To be Burn – Solid Waste
Burner Capacity – 0.2 Kw ( 200 watts )
Capacity – 2 ton per day
Oil Tank capacity of Burner – 300 Lit
Oil pump capacity – 0.4 Kw ( 400 watts ).medical waste Incinerators for burning hospital waste
so we are looking for a source
High Temperature Incineration Procedure HICLOVER YD30
Email: [email protected]
Model | YD-30 | |||
Burning Rate | average 30 kgs/hour | |||
Feed Capacity | average 40 kgs | |||
Paimary Combustion Chamber | 200 Liters | |||
Secondary Combustion Chamber | 100 Liters | |||
Mix Combustion Chamber | Yes | |||
Feed Mode | Manual | |||
Voltage | 220V | |||
Power | 0.59Kw | |||
Fuel Type | Diesel Oil | |||
Burner | Italy Original | |||
Oil Consumption (Diesel Oil) | average 13.3 kg/hour | |||
Gas Consumption (Natural Gas) | *** | |||
Internal Dimensions | 80 x 50 x 50cm (paimary chamber) | |||
External Dimensions | 125 x 90 x 180cm (without chimney) | |||
Temperature Monitor | Yes | |||
Oil Tank Capacity(if oil fuel) | 60 Liters | |||
Door Opening | 40 x 40cm | |||
Chimney Length | 1.0 Meters | |||
Chimney Type | Stainless Steel | |||
Equipment Gross Weight | 1000 kgs |
China Arrests 60 For Waste Incinerator Protests
Early this week, protests erupted in China over plans to build a waste incinerator in an eastern city where officials didn’t seek public approval before proceeding. The demonstrations have been running for more than two weeks and turned violent on Saturday, with hundreds of police descending on to the streets of Yuhang, close to the eastern tourist city of Hangzhou. Previous to this week, officials repeated in state media that they would seek public support for the incinerator, but recently have made dozens of arrests in Hangzhou, with at least 10 demonstrators and 29 policemen injured.
Waste incinerators without proper emission filters can release the carcinogen dioxin, said Wu Yixiu, head of environmental group Greenpeace’s toxics campaign in East Asia. Several neighbors of the Hangzhou site cited that risk and noted that incinerators in Germany were required to filter out the toxin. Following large protests in March against a proposed paraxylene plant in the city of Maoming, officials said they would not proceed with facilities if public resistance remained high.
China’s fast growing cities produce around 160 million tons of domestic waste each year, according to domestic reports, and the country is planning around 300 such incinerators within the next three years as part of a “Great Leap Forward in garbage incineration”. For years, China witnesses tens of thousands of so-called “mass incidents” which have recently been linked to several environmental issues. In March, Li Keqiang, the prime minister, vowed to “declare war” on pollution and said his country would turn its back on “inefficient and blind development.”