Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Incinerator Ignition by Diesel

Required Specifications for Mobile Incinerator
Operational Capabilities
- PROCESS MINIMUM 1 TON PER DAY
- OPERATED WITH LIMITED TRAINING
- REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING
- COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
- ABILITY TO BURN WASTE LUBRICANTS (POL)
- HANDLE ORGANIC SOLIDS (TO INCLUDE RMW)
- DEPLOYABLE
- MOBILE
- 24 HRS OF CONTINUOUS USE
- AUTOMATIC LOADING SYSTEM
- AUTOMATED ASH REMOVAL SYSTEM
- GAS SCRUBBING SYSTEM
- 95% REDUCTION OF SOLID WASTE
- OPERATE OFF DIESEL OR FUEL OIL
- CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
- ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD
- NO PRE-TREATMENT OF WASTE REQUIRED
- FIVE (5) YEAR COMPONENT WARRANTY
Technical Specifications
- OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR
- SET UP AND INSTALLATION INSTRUCTION MANUALS
- BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS
- INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION
- OPERATED AND TRANSPORTED IN 20’ INCINERATORS (CONTAINERS)
- FULL FRONT AND OPTIONAL REAR ACCESS
- PRIMARY / SECONDARY TEMPERATURE CONTROLS
laboratory incinerator china manufacturer
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200
C, thermocouple, air supply capacity 10m3/ minute, power consumption 1.2kWH/ hour, power 3
phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation,
castable, ceramic blanket) and PLC
SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONS
The Waste Incinerator is designed to burn Type IV of pathological waste and infectious, contaminated “red bag,” surgical
dressings, plastic test devices and other wastes.
General Specifications
Burner: 2 burners (primary burner and second burner)
Fuel: Oil
Capacity (Cubic Mtr): 0.65
Ave Capacity: 60 kg per hour
Fuel Consumption (ltrs / hr):13
External Dimensions
Length (mm): 2300
Width (mm): 1220
Height Incl. Flue (mm) 7000
Door Opening (mm) 610 x 710 610 x 710
Operation
Min. Operating Temperature: 950
Max. Operating Temperature: 1320
Residency Time in Second Chamber: 5 sec
Temperature Monitoring: YES
Other clarification
Easy and safe operation
Large counter-balanced fill door with electrical lockout.
Automatic control system provides preset burn times and shut off.
Reload light indicates to operator when it is time to recharge.
Be required for burnout of final charge.
Low energy consumption levels
Programmable digital temperature controls maintain temperature, assuring complete combustion while conserving fuel.
Pressure blower with modulating air control creates turbulence and distributes combustion air to secondary chamber.
Secondary burner with temperature activated modulating control provides fast preheat and sustains high temperature
performance at low energy consumption levels.
Charging rate
portable medical waste incinerator manufacture companies in china
Capacity: 20KG/Hr, Temp Range: 600 Deg. C – 1100 Deg. C
Fuel Supply: Natural Gas/Diesel
Dual Combustion Chamber Complete Scrubbing System (Dual
Resultant Gas Washer), Dual Blower, Chimney Height: 8m
Electric Supply: 220/240Volt, Single Phase
1. Type of waste: Trash
2. Any other type:
3. Quantity of waste generated per day in kg: (50 Ton per day) SOW
4. Duration – incinerator will be used per day: (Minimum 12 hours) SOW
5. Approximate moisture content:
6. Local incinerator operating and emission standards: US-EPA
7. What is the height of the chimney required: Not known
8. Fuel proposed to be used: Deiseal Oil
9. Availability of power and type: 220 or 110
10. Details of space available: Plenty of space
11. Do you require an automatic loading system: [**] Yes [**] No
12. Do you require a gas scrubbing system: [**] Yes [ ] No
13. How soon do you require the system to be delivered: 30
14. Any other specific requirements:
15. Nature: (Solid/Semi-solid/Liquid)
incinerator manufacturer in china
1. Is the residence time more than 2 seconds?
2. Is the primary and secondary air preheated?
3. Could it be provided as a continuous system?
4. Is there a monitoring system for operational parameter? (temperature)
5. Is there a data logging system?
6. Does it provide for control interventions to adjust waste feed, grate speed, and temperature, volume and distribution
of primary and secondary air?
7. Does it include auxiliary burners?
8. Does it include system that automatically stops waste feeding when combustion parameters are not appropriate?
9. Is it possible to have an automatic bottom ash unloading system?
1. Is the primary and secondary air preheated?
2. Could it be provided as a continuous system?
3. Is there a data logging system?
4. Does it provide for control interventions to adjust waste feed, grate speed, and temperature, volume and distribution
of primary and secondary air?
5. Does it include auxiliary burners?
6. Does it include system that automatically stops waste feeding when combustion parameters are not appropriate?
7. Is it possible to have an automatic bottom ash unloading system?
Incinerator
Rated Capacity: 100/KG/Hr
Type of Design: Double Chambered
Mode of Heating: Heating Elements