Supply, delivery,installation and commissioning of a top loader Incinerator

100kg incinerator, medical incinerator 20kg, 150kg capacity incinerator,

Description

SPECIFICATIONS: Incinerator

 

Purpose: Top Loader incinerator of general, medical and dry waste to comply with the requirements of the Air Quality Act, 2004 (Act No 39 of 2004)

 

1 Design standard Retort type, multiple
2 Description of chimney Top mounted, self supporting, unlined
3 Stack height from base At least 11 meter (depends on height above sea level)
4 Incineration performance Capacity 750 kg/hour
5 Temperature Primary Minimum 850 degree Celsius
6 Temperature Secondary Minimum 1000 degree Celsius
7 Dimensions (minimum)(cm)

Length

Width

Height

 

210

180

210

8 Loading door opening (m) 200
9 Description of grate/hearth Full
10 Primary chamber volume (minimum) 1.05 cubic meters
11 Tools included Poker, hoe, rake
12 Materials of construction (minimum)

Case

Bracing

Hearth

 

 

 

Ashing door

Loading door

 

 

 

 

Refractory walls and roof

 

5 mm mild steel

Heavy angle and channel

1550 degree Celsius castable general purpose high strength, high abrasion resistant monolithic refract concrete

High grade cast iron

5 mm mild steel lined with 1550 degree Celsius castable general prupose high strength, high abrasion resistant monolithic refractory concrete

1550 degree Celsius castable general prupose high strength, high abrasion resistant monolithic refractory concrete

 

13 Refractory concrete – alumina content At least 48%
14 Refractory thickness Not thinner than 102 mm but in primary chamber minimum 152 mm and 125 mm thick
15 Insulation to walls 1000 degree castable insulation
16 Chimney stack

Chimney

Diameter of chimney at top

Weight of stack

 

5 mm mild steel

Minimum 430 mm

Approx 500 kg

17 Controls

Barometer damper

Door operated draught limiter

Air supply: built in forced draught heated air primary and secondary (intensifier)

Control panel includes circuit breakers, main switch, timer, 2 set point pyrometer and one set point pyrometer, thermometer

18 Electrical supply required 3-phase
19 Auxiliary fuel Diesel or paraffin
20 Primary burner
21 Secondary (after) burner
22 Type of burners Automatic pressure jet
23 Output Primary Approx 600 000 kJ/hour
24 Output Secondary Approx 750 000kJ/hour
25 Emission control

Heated refractory screen

Low velocity grit arrester screen

Built in
26 Paint case 400 degree Celsius resisting black
27 Paint stack 400 degree Celsius resisting aluminium
28 Temperature of case Not exceeding 90 degree Celsius
29 Intensifier
30 Automatic fan control
31 GRE factor 1.5
32 Noise (primary)

Noise (secondary)

72 dBA
33 Transport and rigging of plant including crane hire 76 dBA
34 Certificate of analysis as per Annexure 1
35 Commissioning of incinerator
36 Guarantee 3 years
37 Training of operators
38 Availability of local distributor for spare sparts

 

ANNEXURE 1

 

Common Name Chemical symbol Compliance: mg/Nm3 under normal conditions of 10% O2, 273 Kelvin and 101.3 kPa
Particulate matter 10
Carbon monoxide CO 50
Sulphur dioxide SO2 50
Oxides of nitrogen NOx expressed as NO2 200
Hydrogen chloride HCl 10
Hydrogen fluoride HF 1
Sum of Lead, arsenic, antimony, chromium, cobalt, copper, manganese, nickel, vanadium Pb+, As+, Sb+, Cr+, Co+, Cu+, Mn+, Ni+, V 0.5
Mercury Hg 0.05
Cadmium Thallium Cd+Ti 0.05
Total organic compounds TOC 10
Ammonia NH3 10
Compliance: ng I TEQ/Nm3 under normal conditions of 10% O2, 273 Kelvin and 101.3 kPa
Dioxins and furans PCDD/PCDF 0.1