INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY

Use diesel, construction in painted steel resistant aluminium at high temperatures, flame device control indicator, charging indicator, temperature control device, burning capacity of 250 kg / hour in two stages (primary  and secondary camera)
INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY
1. CAPACITY OF WASTE DISPOSAL: 50à60 kg / h
2. CAPACITY OF OPERATION WITHOUT STOPPING: 10h
3. SUITABLE FOR WASTE CATEGORIES A, B, C, D AND E MEDICAL WASTE BY UNEP AND WHO
4. COMBUSTION “PYROLYSIS” by controlling the waste gasification
5. CALORIFIC LOWER (LCP) WASTE OF THESE MUST BE OF 3500 KCAL / H. an incinerator with loading indicator, temperature control functions and with two chambers (primary and secondary).
6. TEMPERATURE MAX 1400oC DESTRUCTION
7. MIN TEMPERATURE OF DESTRUCTION 850oC
8. BURNING ROOM NUMBER: 2 (PRIMARY AND SECONDARY)
9. VOLUME CHAMBER: 1200L
10. DIMENSION OF THE LOADING DOOR: 70CMX70CM
11. FUEL TYPE: DIESEL
12. POWER SUPPLY: 220 V / 380 V
13. CHIMNEY HEIGHT: 40 CM
14. BURNER
15. VANTILLATEUR BLOCK
16. BOX CONTROL AND REGULATION.Diesel medical waste incinerator made of  steel painted in aluminum
and resistente to high temperatures,  device  indicator for flame
control, loading indicator, temperature control device, burning
capacity of 250Kg / 10 hours in 2 stages (primary chamber and
secondary chamber.one should burn 50Kg/hr another 600Kg/hr and another, 1000Kg/hr. I have visited your website and would like to ask the following questions:
1. Are these units fueled by natural gas?
2. Do the units ship fully assembled or in pieces?
3. Are smoke stacks included?
4. Can the units be installed within a city area or should they be outside city limits?
5. What floor area does each unit require?
6. What kind of enclosure is required?
7. What is the typical fuel consumption for each unit?

Medical Waste Incinerators for Clinics and Small Hospitals


HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Thing

Serie No.

Part Name

Packing List

1#

Incinerator Mainbody

 

2#

Oil Tank(Deposit)

 

3#

Oil Tank(Daily)

 

4#

Chimney(Vertical,High Temperature)

 

5#

Chimney(Horizontal,High Temperature)

 

6#

Wet Scrubber

 

7#

Chimney(S shape)

 

8#

Chimney(Below)

 

9#

Chimney(Top)

Hospital Incinerators for Medical Waste Destruction

SN

 Thing

Specification

1

Model

TS100

Two

Burning Rate

Ave.50-100Kgs/Hour

3

Feeding Capacity

Ave.200Kgs/Feeding

4

Main Chamber

1000 Liters

5

Secondary Chamber

540 Liters

6

Chimney

Yes

7

Wet Scrubber

Yes

8

Wet Scrubber Parameter

Dia. 100cm Hight 2500cm

9

Feeding Model

Manual

10

Power

380V 3P 50Hz

11

Power

6.0 Kw

12

Gas Form

Diesel Oil

13

Burner

Italy

14

Oil Consumption (Diesel Oil)

Average 20.4 Kgs/Hour

15

Internal Dimensions Main Chamber

120 x 100 x 90 cm

16

External Dimensions (Main Body)

270 x 190 x 170cm

17

Temperature Monitor

Yes

18

Oil Tank (Daily)

1.8M3

19

Oil Tank(Deposit) Parameter

10M3, Dia. 200cm Length 3500cm

20

Feeding Door

80 x 60cm

21

Chimney

6.0 M

22

Chimney Substance

S.Steel

23

Weight

Ave.8500Kgs

24

1st. Chamber Temperature

800℃–1000℃

25

2nd. Chamber Temperature

1000℃-1200℃

26

Residency Time

2Sec.


 

2020-07-27


Sudan Medical waste Treatment Scheme

•    A burn rate of 25 – 30kg/hr.
•    Consists of two chambers to ensure significant reduction of emissions and be capable of temperatures in the range of 800-1000˚c.
•    Incinerator must be of a low maintenance design, be diesel fuelled and need no more than 15 amp 220-250 V power. KW consumption per hour should be stated.
(1)  What  are  main  differences  between  medical  incinerators:    YD-10C  and  TS10(PLC)?
(2)  After  combustion,  the  medical  waste  becomes  smoke?  Without  smell?  No  pollution?
(3)  What  should  we  do  to  release  the  smoke?    Prepare  a  pipe  to  direct  the  smoke  to  factory  outside?
(4)  Any  operation  guide  for  reference,  we  worry  that  it’s  difficult  to  operate?
•    The incinerator should also be able to run off a generator.
•    The incinerator should have option of tank and should use no more than 12L of diesel fuel per hour to burn 25- 30kg of waste.options for medical waste incineration for Kabul, Afghanistan
•    Design must be such to minimize risk to operators and have a simple start sequence to minimize operator training and skills
•    Solid waste reductions in the range of 90 – 97% should be routinely achieved.a central thermal treatment station in the city of Khartoum (9 million inhabitants) we started with two units of autoclave that treat up to 18 tons a day so far, and looking forward to add an incineration plant/s to serve for medical, pharmaceutical, and hazardous waste.

Waste Incinerators International Market Analytics

Key Word:

small incinerators

medical waste incinerator

pet animal cremation incinerator

incinerator manufacturers

 

 

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:

 

Treatment capacity: small scale incinerator, large scale incinerator and incineration pant.

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators

Incinerator fuel: gas incinerator, oil incinerator

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator

Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA) , Haat (India)

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics.  Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste.  Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc.

 

So, why we still use incinerator?

First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control.

Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life.

 

As above two reason but not only above, we still use incinerators.

 

How you can find reasonable incinerator for your local site?

Incinerator is not a cheap equipment, generally the small scale model’s price around $5,000usd per unit and large scale model’s price more than $50,000usd per unit. So, before purchase one unit incinerator, you have to make clear following items:

A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment?

B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size.

C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system.

And other technology items, like power(220v, 380v), waste feed door type, incinerator structure, etc.

 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.

 

laboratory incinerator

the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a special truck

air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).

Incinerators should be provided in the fuel tank (diesel )
? The minimum capacity of the animal carcass incinerator
The destruction of 1000 kg / hour. Incinerator capacity is calculated
8MJ/kg- material and 60 % humidity.
? It must be possible to use the incinerator +40
C to – 15 0C laboratory incinerator
Temperature and 5% – 95% – of moisture conditions.
? PLC controller and a built-in temperature panelita complete
Automatic control, a control computer, which is stored
Information on the variation of temperature with respect to time and
Graphic images.
? must have fuel with automatic control and malfunction
Detection system.
?the ability to pre- warm-up , body waste burning on and off
Consistency is independent of the first and secondary chambers.
? ensuring the incinerator with electricity , it
Must be installed on the generator.
? clean the incinerator should be simple tools ,
Without using any additional equipment

SPECIFICATIONS OF THE MEDICAL BIOLOGICAL WASTE INCINERATOR

SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE  INCINERATOR
It should  be  a three chambered incinerator 
The load capacity of 250 kg
The housing for the incinerator should be able to withstand the temperatures and other operational requirements.
The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc.
It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan.
The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion.
In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere.
A system for continuous emission Monitoring and Environmental Monitoring.
A mechanism with which to treat the waste water before discharge into the sewerage system.
Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation.
Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney).
High power electricity and emergency generator connection for automated ignition purposes.
The chimney should be tall enough and be at least one meter above the tallest building in the vicinity.
The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250.
Other Requirements
Training of all the personnel involved in health care waste (HCW) management.
The Automatic Feeding system of the Incinerator
Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber.
An Automatic bottom ashes discharge system.

HICLOVER Waste Incinerator

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

      

Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste

The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings.

It shall be able to reduce the volume of wastes by 98%.

It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.

 

The incineration should be completely free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a

complete layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its height: 8 m