This model Building is dual/double combustion Room with 02 Components oil burner, batch load incineration Gear.
Items/Model
TS10(PLC)
Picture
Burn Rate
Average 10 kg/hour
Feed Capacity
Average 20kg/feeding
Control Mode
Programmable Logic Controller(PLC) Panel
Combustion Chamber
100L
Internal Dimensions
50x50x40cm
Secondary Chamber
50L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
220V
Power
0.5Kw
Oil Consumption (kg/hour)
typical 8.4kg/hour
Gas Consumption (m3/hour)
typical 10.1m3/hour
Temperature Monitor
Yes
Temperature Protection
Yes
Oil Tank
100L
Feed Door
30x30cm
Chimney
5 Meter
Chimney Type
Stainless Steel
1st. Chamber Temperature
1000℃-1200℃
Residency Time
2.0 Sec.
Gross Weight
1500kg
External Dimensions
140x90x120cm
Combustion Chamber Volume (m3)1.25m3
Gas Retention2-3 Seconds
Operational TemperatureMinimum 850°C for the primary chamber; min 1100
oC for the secondary chamber.
Metal Thickness4mm
Average Ash Residue (%)3%
Dimensions (l, w, h)1.85m x 1.11m x 8.10m
Shipping Weight (kg)Up to 6 tonnes- anything less not acceptable
Fuel Consumption13 – 18 liters per hour
Burn Rate*up to 100kg per hour
Thermostatic DeviceIncluded
Door Size (m)0.64m x 0.54m minimum for ease of loading
StackThe chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account. Point for the measurement of emissions shall be provided.
The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.
Diesel TankA reinforced steel tank with a capacity of min 500 litres. The diesel tank shall come complete with a stand and connection valves.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator
wea are chinese incinerator makers. Nanjing Clover Medical Technology Co., Ltd.. Is a leading waste incinerator maker in China. All show comprised burning capability 10kgs per hour, 30kgs per hour,50kgs each hour,100kgs each hour,150kgs each hour,300kgs each hour,500kgs per hour. So far, all versions sale to all around the world and also have good feedback from end-customer. The YD Model medical incinerator possess multi-combustion room and fundamental dry scrubber (smoke filter chamber) with reasonable endeavor budget. For the cleaner require, we take custom made wet scrubber for incinerator, which will be also our following functioning by focusing on emission technical.
Dual Combustion Chamber: Each of waste incinerator layout with double glazing chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly
Containerized Mobile Incinerator: The incinerator mounted in ISO Container before leave mill, free-installation, no incineration house build structure,movable by truck.
Family Pet Dog&Cat Cremation: Particular design with movable platform, combustion chamber material and custom made for pets crematory enterprise.
Installation and Commissioning: Clover’s engineers instal,train for most of the region and free-cost train in our mill.
• An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight.
• The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source.
• Also consider provision for meeting international emission standards.
Able to handle an average waste production of 100kg/day
“• Minimum load capacity: 20 kg
• Maximum load capacity: 40 kg
• Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day)
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.
b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.
d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.
e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%.
g. include clearly readable system operation panels.
h. include an operator’s manual (in English and French and Spanish).
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding.
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated.
k. can accommodate large variations in waste composition and calorific value.
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank),
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.
“
The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.
We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.
Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.
The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.
System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.
The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.
The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.
HICLOVERis growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.