Lab incinerator china manufacturer


performance at low energy intake levels.
Max. Operating Temperature: 1320
Temperature Tracking: YES
Fuel: Oil

Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200

C, thermocouple, air distribution capacity 10m3/ moment, electricity intake 1.2kWH/ hour, power 3

stage with netral, cooling water sprinkler capability 5L/ moment, completed with refractory (insulation,

castable, ceramic blanket) and PLC

SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR — TECHNICAL SPECIFICATIONS

The Waste Incinerator was created to burn Type IV of pathological waste and infectious, contaminated “red tote,” surgical

dressings, plastic test apparatus and other wastes.
Pressure blower with modulating air controller generates turbulence and distributes combustion atmosphere to secondary space.
Gas Consumption (ltrs / hr):13
Low energy intake levels
Large counter-balanced fill doorway with electric lockout.
Burner:  2 tsp (main burner and second burner)
Ave Capacity: 60 kg per hour
Capacity (Cubic Mtr): 0.65
Min.
External Dimensions
Automated control system offers preset burn times and closed off.
Programmable digital temperature controls maintain temperature, assuring complete combustion whilst conserving fuel.
Operation
Easy and secure operation
Height Incl. Flue (mm) 7000
General Specifications
Residency Time in Second Chamber: 5 sec
Be required for burnout of final charge.