Product Description
- Multiple chamber type, horizontal stationary cylindrical body;
- Capacity of 15 kilograms per hour;
- Diesel-Powered;
- Burners should be monoblock type with built-in fan, motor, electronic programmer, automatic ignition, fuel regulator, registration and security sensor device for the absence of flame triggering solenoid valve mounted on the easel supply;
- The system should have ventilation for sweeping previous gases before activating the fuel supply to the burner;
- Equipped with main combustion chamber and a second chamber for reburning designed to ensure complete combustion of the gases resulting from incomplete combustion of inert gases in the chimney, within the standards recommended by the World Health Organization;
- Equipped with temperature controller to adjust the air of the combustion of the waste, and fuel flow in the burners of the firing chamber and re-burning in order to conserve power when reached the “stead state” of the combustion process;
- The control system must also be provided with an audible alarm in case of decrease in temperature. The characteristic of local power is three-phase 220/127V – 60Hz.;
- The natural circulation of the gases will be induced in a chimney height at least 6 meters and diameter of at least 40 centimeters, so that negative pressure is sufficient to protect the operator from excess of fires or dispersion of noxious gases;
- Supplied with electrical control panel with thermo-magnetic protection and command buttons; and,
- Equipped with pyrometers meters/controller of thermocouple temperature with chromium-aluminium, range 0-1200 Deg C (to observe the temperature of the first and
Second chamber and also of the chimney).